6. When you've finished making settings, press the menu button to return to the record-
ing level (REC LEVEL) setting screen.
Alternatively, you can return by using the P-dial to select and confirm "<- Back" in the
screen.
Gain Decrease
Slope
Threshold
Threshold
Gain Increase
Hold Duration
0s
Slope
Slope
Output level
Output level
Input level
Input level
Gain Decrease (Gain Reduction)
Threshold
(-24.0 ... 0.0 dB, OFF/ Forty-nine steps in 0.5 dB increments: default setting is OFF)
When the incoming signal exceeds the specified threshold value, the gain will be re-
duced so that the input signal is below that threshold value.
Slope
(-24.0 ... -0.5 dB/s. Forty-eight steps in 0.5 dB increments: default setting is 6.0 dB/s)
This specifies the time (envelope setting) over which the gain is adjusted when the above
Threshold value is exceeded.
Gain Increase
Threshold
(OFF, -36.0 ... 0.0 dB/ Seventy-two steps in 0.5 dB increments: default setting is -36.0 dB)
Hold
( 1 ... 30s/ Thirty steps in 1-second increments: default setting is 10s)
If the input signal does not exceed the Threshold value for the duration specified by the
Hold setting, the input gain will be raised according to the Slope setting.
Slope
(0.5 ... +24.0 dB/s. Forty-eight steps in 0.5 dB increments: default setting is +6.0 dB/s)
This specifies how the gain will be adjusted when the Threshold value is exceeded.